Wall Claddings
Knauf Lining System
Knauf Lining System can select various
Knauf gypsum boards as veneer to meet different performance
requirements. The board is fixed on the lightweight steel frame composed
of Knauf CD 60 profile, Knauf universal bracket and Knauf UD 28
perimeter channel.
Features:
- Relative large clear distance between
lining wall and base wall, which is convenient for filling insulation
materials and laying large pipelines.
- It is suitable for the wall with uneven surface.
- Wide range of applications and no need of pre-treatment of base wall surface.
System components:
It is the CD 60 x 27/ 0.6mm profile, which is the main component of Knauf lining system
It is used for extending CD profile.
It is the UD 28x27x 0.5mm profile, which can serve as the channel along top and bottom.
It can fix the Knauf CD profile onto wall surface. EN BS & DIN
Wall linings
Single layer or Double layer

- Height up to
~10.00m - Improve Thermal and Acoustic Insulation

Wall linings, independent
Single layer or Double layer
- Improves Thermal and Acoustic Insulation
- Height up to 5.4 meter

W623 System
Knauf W623.ae Linings may be specified with confidence for application to most masonry backgrounds depending on the condition.
- Where a variable stand-off clearance is required between lining and background of between 27 and 125mm.
- Where background is not aligned properly.
- Where insulation is required within the wall lining void.
- Where deep service runs are required to be accommodated within the lining void.
Knauf Linings can accommodate any of the range of Knauf Gypsum
Boards, depending on the performance requirements. The boards are fixed
onto a lightweight metal framework of Knauf 'CD' Channels fixed to Knauf
Universal Brackets and Knauf 'UD' Channels.
The system can provide a variable stand-off from the background of
between 27 and 125mm. This makes it capable to override substantial
irregularities in the background.
The lining void facilitates the introduction of thermal or acoustic insulation and provides containment for service runs.
The system can be applied to the majority of all common building
substrates. Pretreatment of the background is not required. Under good
building practice, however, any deleterious deposits, such as mould, oil
or grease, should be removed as a precaution.
The tapered edge boards can be taped and jointed using Knauf Jointing
Compounds (such as Knauf Fugenfüller or Knauf Readygips ) and
Accessories. Knauf Readygips can be applied as a skim coat to achieve a
smooth plastered finish.
W623 (Single Layer with Insulation)
W625 System
Knauf W625.ae Linings may be specified with confidence for application to most masonry backgrounds depending on the condition.
- Where a variable stand-off clearance is required between lining and background of between 27 and 125mm.
- Where background is not aligned properly.
- Where insulation is required within the wall lining void.
- Where deep service runs are required to be accommodated within the lining void.
Knauf Linings can accommodate any of the range of Knauf Gypsum
Boards, depending on the performance requirements. The boards are fixed
onto a lightweight metal framework of Knauf 'CD' Channels fixed to Knauf
Universal Brackets and Knauf 'UD' Channels.
The system can provide a variable stand-off from the background of
between 27 and 125mm. This makes it capable to override substantial
irregularities in the background.
The lining void facilitates the introduction of thermal or acoustic insulation and provides containment for service runs.
The system can be applied to the majority of all common building
substrates. Pretreatment of the background is not required. Under good
building practice, however, any deleterious deposits, such as mould, oil
or grease, should be removed as a precaution.
The tapered edge boards can be taped and jointed using Knauf Jointing
Compounds (such as Knauf Fugenfüller or Knauf Readygips) and
Accessories. Knauf Readygips can be applied as a skim coat to achieve a
smooth plastered finish.
W625 Single Layer (With Insulation & Defl. Head)
W625 Double Layer (With Insulation & Defl. Head)
|